POLYBOND™ 136

POLYBOND™ 136

Cementitious Tile Adhesive

Product Group:

Adhesive & Grout System

POLYBOND™ 136 is a polymer modified water resistant cement-based tiles adhesive for vertical and horizontal installation of small to medium sized ceramic tiles. It is highly recommended to be mixed with POLYBOND™ ADD-Mix to replace water for increased performance.

Advantages

  • User friendly
  • Good bond strength
  • Good open time
  • Excellent workability
  • No pre-soaking of tiles
  • Non-toxic and non-flammable

Recommended Substrate

Base cement-sand site mix plaster or screed.
Factory premix render or screed.

not Recommended

POLYBOND™ 136 is not recommended for use on wood, metal, plastic, cement asbestos board or painted surfaces.

Application method and thickness

POLYBOND™ 136 with Latex is highly suitable to be used for both internal and external application with recommended average bedding thickness of 3 to 5 mm, using the Single Bonding Method of Notched Troweling onto substrate.

Single Bonding Method

  • Notched troweling onto substrate and install tiles progressively at not more than a rate of 1m²/time.
PHYSICAL PROPERTIES
Components: Water soluble polymers & chemical additives, dry graded silica sand > 95% SiO2, non reactive limestone fillers and portland cement
Colour Availability: Grey
Maximum Grain Size: 1.00 mm
Dry Density in kg/litre: 1.35
Wet Density in kg/litre: 1.85
APPLICATION DETAILS
Coverage @ full body: Approx. 1.350 kg/m²/mm
Coverage @ notched trowel: Approx. 0.675 kg/m²/mm
Recommended Bed Thickness: 3 - 5 mm
Coverage: Approx. 4 - 6 kg/m² at 3 - 5 mm (please refer to "Table for Coverage")
Open time: Approx. 10 - 15 minutes
Pot life: Approx. 1 - 2 hours
Adjustability time after placement: Approx. 10 minutes
Setting time: 16 hours
Mixing Ratio: 6.5 - 7.5 litres of POLYBOND™ ADD-Mix
Resistance to mild acid: Fair
Resistance to dampness: Good
Thermal expansion: Similar to concrete
  • Clean surface to remove oil, dust, laitances and any unsound material by soft brushing and/or vacuuming. Surface should preferably have a texture similar to light broom finish.
  • Base cement-sand site mix plaster or factory premix render must be cured (minimum 28 days), wood floated or steel trowelled to desired flatness of 2mm over 1.2m tolerance, free from loose particles, grease, oil and not to be subjected to further shrinkage crack after tiles installation and best not to have vibration in the vicinity during tiles installation.
  • Check the verticality and alignment of the base plaster to avoid thick application of adhesive. Otherwise, apply a levelling coat of POLYMIX® Coarse or POLYMIX® Fine Mortar Base Coat to level to the desired flatness of 2mm over 1.2m tolerance.
  • All the levelling coat if any onto the base plaster must be at least 1 month old prior to tiles installation
  • Check the flatness to ensure no hollowness, cracking and conform to flatness required and dampen by light misting with water if too dry to reduce rapid water absorption. Repair all defects or redo whenever necessary.
Mix thoroughly a bag of 25kg POLYBOND™ 136 with approximately 6.0 – 7.0 litres of POLYBOND™ ADD-Mix with a power mixer and mix continuously for 3 – 5 minutes until a homogeneous paste is achieved. Re-mix the material before re-use if the material is left undisturbed for more than 30 minutes.
Firmly apply freshly mixed POLYBOND™ 136 with a notched trowel onto substrate to achieve good contact and build up to the required thickness within the recommended range. Lay the tiles immediately and progressively onto the fresh adhesive bed and firmly fix it to ensure good contact between the tiles and substrate. Tiles must be fully bedded with POLYBOND™ 136 and ensure voids on underside of tiles. Any adjustment of tiles shall be done within 10 minutes after installation with POLYBOND™ 136. Any tile adjustment beyond this time shall require the removal of the existing adhesive and the substrate shall be applied with a fresh coat of POLYBOND™ 136. For each application, do not apply POLYBOND™ 136 beyond a working area that cannot be completed within 10 minutes. Remove surplus adhesive from the tile surface and joints with a damp cloth. Avoid installation of the tile grout and any heavy loading of newly installed tile surface within 24 hours.
  • Install the tiles immediately and progressively onto the fresh adhesive bed and to continuously ensure good contact between the tiles and substrate by pressing the tiles firmly with a slight twisting action. Tiles must be fully bedded with POLYBOND™ 136 to ensure voids free beneath the tiles. Gently tap the tiles to the finish level and position for maximum contact with the adhesive.
  • Re-trowel over the area of the adhesive to break the skin if skinning (a shinny and glossy appearance) has started to form prior to tiling.
  • Any adjustment of tiles shall be done within 5-10 minutes after installation of POLYBOND™ 136. Any tile adjustment beyond this time shall require the removal of the existing adhesive and the substrate shall be applied with a fresh coat of adhesive.
  • For each application, do not apply POLYBOND™ 136 beyond a working area that cannot be completed within 5-10 minutes. Remove surplus adhesive from the tile surface and joints with a damp cloth. Avoid installation of the tile grout and any heavy loading of newly installed tile surface within 24 hours.
  • It is recommended to leave a minimum of 3mm at tile joints in between all tiles for ease of grouting and expansion/contraction purpose.
Packing: 25kg/bag
Shelf Life: 6 months in original packing
Storage: Keep in cool and dry condition
  • Do not dilute/adulterate the POLYBOND™ 136 with OPC/sand/additional additive other than recommended.
  • Do not dampen the applied adhesive to artificially prolong open time.
  • Light foot traffic is only allowable after a minimum of 24 hours.
  • Tile joint grouting after 8 hours (wall) and 24 hours (floor).
  • Protect the applied adhesive against high humidity or running water until the material is fully cured.